HW Setting 9 Model Info À£µ¦½º Fuel Cell Test Station Version Info 22.07.07 Gas Valve Control 4 Element 4 dispName H2 inv? 0 value 0 DAQ Port (DO) Dev1/port0/line0 Element 4 dispName N2 inv? 0 value 0 DAQ Port (DO) Dev1/port0/line1 Element 4 dispName Air inv? 0 value 0 DAQ Port (DO) Dev1/port0/line2 Element 4 dispName N2 inv? 0 value 0 DAQ Port (DO) Dev1/port0/line3 Mess Flow Control 2 Elements 3 setFlow 6 value 0.00000000000000 min 0.00000000000000 max 1000.00000000000000 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AO) Dev1/ao0 getFlow 6 value 0.00000000000000 min 0.00000000000000 max 1000.00000000000000 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AI) Dev1/ai0 dispName Anode [sccm] Elements 3 setFlow 6 value 0.00000000000000 min 0.00000000000000 max 4999.99999999999999 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AO) Dev1/ao1 getFlow 6 value 0.00000000000000 min 0.00000000000000 max 4999.99999999999999 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AI) Dev1/ai1 dispName Cathode [sccm] Temperature Control 4 Elements 3 setTemp 6 value 0.00000000000000 min 20.00000000000000 max 90.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 0 getTemp 6 value 0.00000000000000 min 20.00000000000000 max 90.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 0 dispName A. Hum. [¡ÆC] Elements 3 setTemp 6 value 0.00000000000000 min 20.00000000000000 max 90.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 1 getTemp 6 value 0.00000000000000 min 20.00000000000000 max 90.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 1 dispName C. Hum. [¡ÆC] Elements 3 setTemp 6 value 0.00000000000000 min 20.00000000000000 max 120.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 2 getTemp 6 value 0.00000000000000 min 20.00000000000000 max 120.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 2 dispName A. PreH. [¡ÆC] Elements 3 setTemp 6 value 0.00000000000000 min 20.00000000000000 max 120.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 3 getTemp 6 value 0.00000000000000 min 20.00000000000000 max 120.00000000000000 factor 0.00000000000000 offset 0.00000000000000 Serial CH 3 dispName C. PreH. [¡ÆC] Digital Control 1 Element 4 dispName Water Pump inv? 0 value 0 DAQ Port (DO) Dev1/port0/line5 Digital Measure 0 Element 4 dispName inv? value DAQ Port (DI) Analog Control 0 Elements 2 getTemp 6 value min max factor offset DAQ Port (AI) dispName Analog Measure 2 Elements 2 getTemp 6 value 0.00000000000000 min 0.00000000000000 max 100.00000000000000 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AI) Dev1/ai6 dispName A. Inlet [bar] Elements 2 getTemp 6 value 0.00000000000000 min 0.00000000000000 max 100.00000000000000 factor 0.00000000000000 offset 0.00000000000000 DAQ Port (AI) Dev1/ai7 dispName C. Inlet [bar]